Your Location
Select Your Local Area
----- United States -----
Not Listed
Alabama
Alaska
Arkansas - Northwest Corner
Arkansas - Balance
Arizona
California - Northern
California - Southern
Colorado
Connecticut
Florida - Northern
Florida - Central
Florida - Southern
Georgia - Northern
Georgia - Central
Georgia - Southern
Hawaii
Idaho - Northern
Idaho - Southern
Illinois - Northern
Illinois - Southern
Indiana
Indiana - Bordering Cincinnati
Indiana - Northwest Corner
Iowa
Kansas
Kentucky
Lousiana
Maine
Maryland
Massachusetts
Michigan
Michigan - Upper Penninsula
Minnesota
Mississippi
Missouri - Eastern
Missouri - Western
Montana
Nebraska
Nevada
New Hampshire
New Jersey - Northern
New Jersey - Southern
New Mexico
New York City
New York - Central
New York - Long Island
New York - Upstate
New York - Western
North Carolina
North Dakota
Ohio - Northern
Ohio - Southern
Oklahoma
Oregon
Pennsylvania - Eastern
Pennsylvania - Western
Rhode Island
South Carolina
South Dakota
Tennessee - Central
Tennessee - Eastern
Tennessee - Western
Texas - Brownsville
Texas - Dallas
Texas - El Paso
Texas - Houston
Texas - San Antonio
Utah
Vermont
Virginia
Virginia - Northern
Washington
Washington DC
West Virginia
Wisconsin
----- Canada -----
Ontario - Eastern
Ontario - Western
Quebec
Nova Scotia
New Brunswick
Manitoba
British Columbia
Prince Edward Island
Saskatchewan
Alberta
Newfoundland
----- Central & South America -----
Mexico
Peru
Puerto Rico
----- International -----
All Others Outside Of North America
Boiler Make
Select Manufacturer or Type
--- Atmospheric Boilers ---
Ajax Atmospheric Burner
Rite Atmospheric Burner
To be Advised
--- Commercial Hot Water Boilers ---
Buderus
Burnham Commercial
Camus
Columbia
DeDietrich
Hydrotherm
LES
Lochinvar
Patterson Kelley
RBI
Rite Power Burner
Smith
Triad Boiler
Weil McLain
--- Firetubes (Scotch Marine) ---
Boilersmith
Burnham
Columbia
Continental
Cleaver-Brooks
Cyclotherm
Donlee
Eclipse
English Boiler
Easco
Hurst
Industrial
Johnston
Kewanee
Myrggo
North American
Sellers
Superior Apache
Superior Arrowhead
Superior Aztec
Superior Mohawk
Superior Mohican
Superior Seminole
Superior Super Seminole
Superior (other)
Tecnolog
Triad Boiler Systems
Victory Energy Three-Pass
Victory Energy Four-Pass
Williams and Davis
York-Shipley
Unlisted Firetube
--- Flextube Watertubes ---
Bryan
English BTBF
Novatherm
Unilux Flextube
Universal Boiler Works
Unlisted Flextube
--- Industrial Watertubes (D-A-O-S Types) ---
ABCO
Aalborg
B & W
Bigelo
Cleaver-Brooks D-Type
Clayton
Combustion Engineering
English Boiler
Erie City
Foster Wheeler
Fulton
IBW
Indeck-Keystone
Keeler
McBurney
Murry Trane
Nebraska
Rentech
Tecnolog
Titusville
Unilux
Union Iron Works
Vapower
Victory Energy
Volcano
Zurn
Unlisted Industrial Watertube
Boiler Capacity
HP
PPH
BTUH
TONS
KW
KPH
Inlet Water Temp
Water & Gas Temperature Units
deg F deg C
Firing Rate
Load Condition 1100 % Firing
Load Condition 2 % Firing
Load Condition 3 % Firing
Load Condition 4 % Firing
Inlet Flue Gas Temp
Load 1 Required
Optional
Optional
Optional
Flue Gas Temp @ 100% Load is Only Required Entry - Part Load Temperatures are Automatically Calculated if Left Blank
Annual Hours @ Firing Rate
Excess Air
15 3 5 8 10 12 15 17 20 25 30 35 40 45 50 55 %
15 3 5 8 10 12 15 17 20 25 30 35 40 45 50 55 %
15 3 5 8 10 12 15 17 20 25 30 35 40 45 50 55 %
20 3 5 8 10 12 15 17 20 25 30 35 40 45 50 55 %
Flue Gas Recirculation Rate
0 5 15 20 25
30 35 40 45 50
%
FGR Taken Before Economizer
FGR Taken After Economizer
Unit Selection
SHORTY - Coiled Unit - Ideal to 300 HP
BOSS - Base Model
MAGNUM - Mid-Range Recovery
SUPER - High Recovery Unit
TITAN - For Largest Boilers
BYPASS SHORTY :
Disables Bruce from consideration of coiled units
Fuels Fired
6 Fins per Inch - Gas Only
5 Fins per Inch - Gas Firing With Standby #2 Oil
4 Fins per Inch - Gas and/or Consistent #2 Oil Firing
3 Fins per Inch - Heavy Fuel Oil Firing
2 Fins per Inch - Wood Firing
Current Boiler Efficiency
0.81
0.80
0.79
0.78
0.77
0.76
0.75
0.74
0.73
0.72
0.71
0.70
0.65
0.82
0.83
0.835
0.84
0.845
0.85
0.86
0.87
0.88
%
Blowdown Rate
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
% - For boiler feedwater applications only
Stack Diameter
0
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
in
Leave 0 if diameter unknown
Draft Inducer
Not required - use boiler fan to overcome pressure drop
Incorporate fan-assisted draft inducer. Supply by others.
Fuel Price
9.50
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
6.50
6.75
7.00
7.25
7.50
7.75
8.00
8.25
8.50
8.75
9.00
9.25
9.50
9.75
10.00
10.25
10.50
10.75
11.00
11.25
11.50
11.75
12.00
12.25
12.50
12.75
13.00
13.25
13.50
13.75
14.00
14.25
14.50
14.75
15.00
15.25
15.50
15.75
16.00
16.25
16.50
16.75
17.00
17.25
17.50
17.75
18.00
18.25
18.50
18.75
19.00
19.25
19.50
19.75
20.00
20.25
20.50
20.75
21.00
21.25
21.50
21.75
22.00
22.25
22.50
22.75
dollars per million btu
Maximum Water Side Pressure Drop
15
20 5
10
PSI
Optional Selections Below
Custom Water Flow RateOptional
PPH
GPM
Check to allow flow rate to track firing rate.
Enter the water flow rate ONLY if the flow rate will differ from the boiler capacity flow rate.
This feature is for economizers used in a non-traditional installation such as process water heating.
If your application is a typical boiler economizer arrangement then leave this cell blank and leave units on PPH.
Two-Stage EconomizersOptional
Check to Select Two-Stage Economizer Unit
Enter Second Stage Water Inlet Temperature
PPH
% Make-Up
Enter Second Stage Water Flow
Second Stage maximum Water Side Pressure Drop:
15
20
5
10
PSI
Check to allow flow rate to track firing rate.
Click for Split-Titan - Lowest Cost Two-Stage for boilers over 400 HP
Click for Unbalanced-Titan placing 3/4 of total heating surface in 2nd stage, condensing section
Bruce chooses the optimum configuration (recommended)
Force a Stacked Two-Stage
Force a Side-By-Side Two-Stage
Enter the water flow rate ONLY if the flow rate will differ from the boiler capacity flow rate.
This feature is for economizers used in a non-traditional installation such as process water heating.
If your application is a typical boiler economizer arrangement then leave this cell blank and leave units on PPH.
Stacked EconomizersOptional
Do Not Stack Units
Double-Stack Units
Triple-Stack Units
Stacking economizers is a way of increasing heat recovery by placing two identical units inside of
a common casing.
Targeted Flue Gas Exit TemperatureOptional
Enter Target Gas Exit Temperature
Stay with Model Selected
Increase Model Size
If you need a unit to meet a specific flue gas exit temperature enter the value in the above data field
and Bruce will manipulate various designs to come as close as possible.
Stainless Tube OverrideOptional
Override ON - All tubing will be stainless steel
Override OFF - Bruce will select optimum tube material
By default units with deaerated water will be supplied with carbon steel tubes, all other applications
and all Shorty units have stainless steel tubes. Should you wish to override the carbon steel tube
selection for deaerated applications and utilize a stainless steel tube click the button above.
Water Specific HeatOptional
1.0
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
for glycol systems
Specification Assistant
Bruce can assist with selections for projects with industry standard specifications. If you are bidding to
one of the specifications below simply click the appropriate spec and Bruce will adapt the proposal to address.
No Specification Default
Default. Standard HeatSponge supply. No specifications involved.
Veterans Administration Hospital SpecificationOptional
Standard VA Hospital specifications are riddled with conflicts and
mistakes such as the the supply of stainless tubes to Section 1 construction; stainless is not permitted per Section 1
of the ASME Boiler Code. Words in orange require you to conform to the specific spec.
Select Compliance & Clarifications to Standard VA Specification:
A. Heat exchangers to transfer heat from boiler flue gases to boiler feedwater.
B. Type: Rectangular configuration, replaceable finned tubes, up flow flue gas, parallel flow water,
insulated casing with removable panels allowing access to all tubes for cleaning and replacement. Arrange tubes
to permit lane type soot blowing.
Flue gas bypass damper
Flue gas bypass damper IS NOT required
Flue gas bypass damper IS required
C. Performance: Refer to schedules on drawings. Coordinate input flue gas temperatures with data from boiler manufacturer.
D. Construction:
Comply with ASME Boiler and Pressure Vessel Code, Section 1. Design unit to permit operation with no water in the tubes at the temperature listed below.
Design Pressure:
a. Water Tubes, 2050 kPa (300 psi) minimum.
b. Inner Casings, 2.5 kPa (10 inches water column) minimum.
Design Temperature, 370 C (700 F).
Tubes and Headers: ASTM A254, Type 316 Stainless steel. Helically wound non serrated stainless steel fins continuously welded to tubes. 2050 kPa (300 psi) flanged piping connections.
Drainable by gravity. Return bend areas shall be exposed to the bulk temperature of the flue gas.
Headers shall be external to the casing. Fin density shall not exceed
48 fins per foot.
60 fins per foot.
Maximum fin height, 13 mm (0.5 inches).
Casing: Double wall, removable panels, with insulation between walls. 80 mm (3 inch) angle flanges on flue gas inlet and outlet for attachment of breeching and stack.
a. Inner Casing, stainless steel, all welded. Steel angles for breeching attachment to casing. Entire casing systems must be gas tight.
b. Insulation: Mineral fiber, ASTM C612, 50 mm (2 inches) thick.
c. Outer Casing: Galvanized or painted steel, 0.4 mm (0.016 inches) thick.
E. Accessories:
Safety Relief Valve: Valve designed for steam and water service, ASME National Board certified, selected by economizer manufacturer in accordance with ASME Code requirements.
Soot Blowers: Provide sufficient number of blowers to clean all tube areas. Location, arrangement and quantity based on recommendations of soot blower manufacturer for type and size of economizer furnished. Soot blowing shall be lane type.
Sootblowers ARE NOT specified
Rotating valve-in-head sootblower IS specified
Oscillating ring assembly sootblower with timer in remote control panel IS specified
Inlet and Outlet Transitions: Designed and furnished by economizer manufacturer.
Instrument package
Instrumentation package IS NOT required
Instrumentation package IS required
Stack corrosion control system: Automatically modulate an internal stack gas damper to control the temperature
of stack gases leaving economizer as measured by stack temperature sensor.
Corrosion control system IS NOT specified
Corrosion control system IS specified
F. Factory Test and Inspections: Inspect the completed economizer assembly in accordance with the ASME Boiler and Pressure Vessel Code, Section I. Certify the inspection and submit four copies of completed ASME Form P 3 for each economizer.
Two Inch Diameter Tube All Welded EconomizersOptional
These specifications are rooted in 1950's era design practices and are generally considered to be obsolete for all boilers under 100,000 pph capacity.
These relics from a bygone boiler era do not offer the ability to utilize anything other than carbon
steel greatly limiting their flexibility and options for applications.
The all welded tube and casing design offers no practical ease of repair throughout its life.
Select Compliance & Clarifications to typical Two Inch Tube Wedled Construction specification:
This feature is also a very good way
to compare the performance of a competitive unit to a HeatSponge. If you are comparing
units and the competitive unit has a higher gas side pressure drop than our AutoPick selects
use this feature to see how a HeatSponge would compare to the competitive selection. Some competitors
will try to sell a smaller unit with an excessively high backpressure simply to offer a lower price.