HeatSponge Boiler Economizers
Economizers Designed to Outlive Your Boiler
On-Line Pricing, Performance, and Proposal Generator
Featuring Bruce, Your On-Line Sales Engineer
This is Bruce's economizer data input page. The process for obtaining a quote is easy. If you have any questions
as you proceed always feel free to ask Bruce, our on-line sales engineer, for helpful comments.
Click the blue Info icon beside the parameter in question to ask for Bruce's information on the data field.
Bruce's "brain" currently consist of approximately 17,000 lines of code (we think, it is hard to keep count anymore) that reflects years of programming
effort and represents a combined knowledge base from its creators of over a half of a century.
We created Bruce to provide our customers the most complete and fastest economizer selection
package that has ever been made available to the boiler industry.
The Proposal Recall feature can be found at the very bottom of this page. This will allow a user
to recall a previously completed proposal.
Click here to meet Bruce, Your On-Line Sales Engineer
A brief tutorial is also provided for new users of this software.
Click here for the Selection Tutorial .
Bruce's Required Data: this data is required to make a preliminary selection.
Need Advice on the Local Contact Data Field? Click to Ask Bruce
Select Your Local Area
----- United States -----
Not Listed
Alabama
Alaska
Arkansas - Northwest Corner
Arkansas - Balance
Arizona
California - Northern
California - Southern
Colorado
Connecticut
Florida - Northern
Florida - Central
Florida - Southern
Georgia
Hawaii
Idaho - Northern
Idaho - Southern
Illinois - Northern
Illinois - Southern
Indiana
Indiana - Bordering Cincinnati
Indiana - Northwest Corner
Iowa
Kansas
Kentucky
Lousiana
Maine
Maryland
Massachussetes
Michigan
Michigan - Upper Penninsula
Minnesota
Mississippi
Missouri - Eastern
Missouri - Western
Montana
Nebraska
Nevada - Clark County
New Hampshire
New Jersey - Northern
New Jersey - Southern
New Mexico
New York City
New York - Central
New York - Long Island
New York - Upstate
New York - Western
North Carolina
North Dakota
Ohio
Oklahoma
Oregon
Pennsylvania - Eastern
Pennsylvania - Western
Rhode Island
South Carolina
South Dakota
Tennessee - Central
Tennessee - Eastern
Tennessee - Western
Texas
Utah
Vermont
Virginia
Virginia - Northern
Washington
Washington DC
West Virginia
Wisconsin
----- Canada -----
Ontario
Quebec
Nova Scotia
New Brunswick
Manitoba
British Columbia
Prince Edward Island
Saskatchewan
Alberta
Newfoundland
----- Central & South America -----
Mexico
Peru
----- International -----
All Others Outside Of North America
Select Your Local Contact: Required Data
Local sales and support offices are located all over the country to assist in the
selection, procurement, and installation of a HeatSponge economizer.
Need Advice on the Boiler Capacity Data Field? Click to Ask Bruce
HP
PPH
BTUH
Enter Boiler Capacity: Required Data
You may enter your boiler capacity in Boiler Horse Power (HP), Boiler Pounds per Hour (PPH)
capacity, or BTU input per hour (BTUH). Firetube boilers are typically rated in HP while watertube
boilers are rated in PPH. Smaller commercial boilers rated in BTU input require the input to be entered
in million BTU per hour, for example a 1,500,000 btu/hr unit should be entered as 1.5 in the data entry area.
Need Advice on the Inlet Water Temperature Data Field? Click to Ask Bruce
Economizer Inlet Water Temperature F: Required Data
Water inlet temperatures under 215 F will be considered non-deaerated - stainless
steel tube required and will be included. Note if the economizer is to be used for a process water
(non-boiler feedwater) application you will have the opportunity to enter a custom water flow rate lower on this page.
Need Advice on the Inlet Flue Gas Temperature Data Field? Click to Ask Bruce
Economizer Flue Gas Inlet Temperature F At High Fire: Required Data
If you're not sure:
Firetube: If unknown assume 75 degrees above saturated steam temperature
Watertube: If unknown assume 150 degrees above saturated steam temperature
Click here for steam tables to see saturated steam temperatures
Optional Part-Load Gas Temperature Inputs Available Below in Optional Input Section.
Need Advice on the Boiler Type Data Field? Click to Ask Bruce
Boiler Manufacturer Economizer Will Be Installed On: Required Input
Select Manufacturer or Type
--- Atmospheric Commercial Boilers ---
To be Advised
--- Firetubes (Scotch Marine) ---
Burnham
Columbia
Continental
Cleaver-Brooks
Cyclotherm
Donlee
Eclipse
English Boiler
Hurst
Industrial
Johnston
Kewanee
Myrggo
North American
Sellers
Superior Apache
Superior Aztec
Superior Mohawk
Superior Mohican
Superior Seminole
Superior Super Seminole
Superior (other)
Tecnolog
Triad Boiler Systems
York-Shipley
Unlisted Firetube
--- Flextube Watertubes ---
Bryan
English BTBF
Unilux Flextube
Universal Boiler Works
Unlisted Flextube
--- Industrial Watertubes (D-A-O-S Types) ---
ABCO
Aalborg
B & W
Bigelo
Cleaver-Brooks D-Type
Clayton
Combustion Engineering
English Boiler
Erie City
Foster Wheeler
Fulton
Indeck-Keystone
Keeler
Murry Trane
Nebraska
Rentech
Tecnolog
Unilux
Union Iron Works
Vapower
Victory Energy
Volcano
Zurn
Unlisted Industrial Watertube
We recommend you enter the manufacturer of the boiler if known as some boilers, primarily firetube boilers,
have a lower tolerance for flue gas backpressure. Not selecting any specific manufacturer will result
in the use of default data for the boiler type selected.
Mouseover for Additional Information Window
All performance based on counter-flow piping arrangement only.
End of required data requirements for typical HeatSponge Applications. This is a minimum requirement,
final unit selection could be affected by other operational constraints. Additional data inputs are located below.
HeatSponge reviews all selections for accuracy prior to placement of any purchase order.
End of required and optional data requirements for typical HeatSponge Applications. This is a minimum requirement,
final unit selection could be affected by other operational constraints. HeatSponge reviews all of Bruce's prelimianry selections
for accuracy prior to placement of any purchase order.
Only experienced boiler professionals should adjust the data below.
Manual Unit Selection / Bypass Bruce - For Experienced Boiler Technicians Only:
AutoPick ON
AutoPick OFF - Manual Selection below
Experienced boiler professionals may bypass Bruce's AutoPick software and manually
select a maximum gas side pressure drop from the selection chart below. Just because a data page
will be printed out means HeatSponge confirms that a manually selected unit will work on a given boiler.
Excessive backpressure will seriously impact boiler operation.
This feature is also a very good way
to compare the performance of a competitive unit to a HeatSponge. If you are comparing
units and the competitive unit has a higher gas side pressure drop than our AutoPick selects
use this feature to see how a HeatSponge would compare to the competitive selection. Some competitors
will try to sell a smaller unit with an excessively high backpressure simply to offer a lower price.
Select Maximum Allowable Backpressure:
0.05
0.06
0.07
0.08
0.09
0.10
0.12
0.15
0.17
0.20
0.22
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.90
1.00
1.25
1.50
1.75
Flue Gas Mass Flow Calculation Override - For Experienced Boiler Technicians Only:
Experienced boiler professionals may custom select the flue gas mass flow rate. You must both enter the mass flow number to use as well
as check the override checkbox.
Enter the custom mass flow rate in pph in this box
Bypass checkbox required
Alternate Water-Side Fluid Specific Heat - For Experienced Boiler Technicians Only:
Experienced boiler professionals may custom select the water-side fluid specific heat for non-water economizer applications.
This would be typically utilized for glycol or thermal fluid heating applications. If your application is a typical boiler
water application then leave at 1.0 and do not change anything!
Select Water-Side Fluid Specific Heat:
1.0
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
Maximum Water Side Pressure Drop:
15
20
5
10
PSI For Experienced Boiler Technicians Only
You can change the maximum water side pressure drop that the economizer can accommodate.
Excess Air - For Experienced Boiler Technicians Only:
Experienced boiler professionals may custom select the excess air of the burner. Most typical burners
operate at 15% excess air at 100% load.
Select Excess Air at 100% Load:
10
3
5
8
12
15
17
20
25
30
35
40
45
50
55
%
Select Excess Air at 75% Load:
15
3
5
8
10
12
17
20
25
30
35
40
45
50
55
%
Select Excess Air at 50% Load:
15
3
5
8
10
12
17
20
25
30
35
40
45
50
55
%
Select Excess Air at 25% Load:
20
3
5
8
10
12
15
17
25
30
35
40
45
50
55
%
Note: At this time our software is designed for rating boilers firing natural gas only. #2 oil
performance will be close. Contact us if you require assistance.
The AutoPick software is based on the industry-standard Escoa approach to heat transfer. An industry
standard, this proven and publicly available series of heat transfer equations can be relied on for providing
accurate and consistent heat transfer ratings. All units that are awarded are further reviewed on a third-party software
to insure accuracy with the preliminary online performance. We reserve the right to limit or deny access to
the software for any reason and completely at our discretion.
Final unit selection could be affected by other operational constraints. HeatSponge reviews all selections
for accuracy prior to placement of any purchase order.
Proposal Recall Feature : This allows for the recall of prior-entered proposals. Please reference
the Proposal Number and unique Password provided on the prior-completed proposal and enter below.
Copyright © 2008 Heatsponge.com All rights reserved.